Principles Of Non-Invasive Blood Glucose Measurement
valerie67w663 於 1 月之前 修改了此頁面


Non-invasive blood glucose monitoring by NIR spectroscopy has evolved over decades as a promising various to finger-prick strategies. However, despite vital analysis, regulatory approval remains elusive. 99.26%, suggesting clinical relevance-but regulatory requirements explicitly exclude non-invasive formats. Major consumer electronics firms (e.g., Samsung, Apple, Rockley Photonics) are actively developing Raman and NIR-based wearables. While the FDA warns in opposition to premature claims, these efforts mirror fast progress even amid FDA’s warning. NIR relies on overtone and combination vibrational bands of glucose’s C-H, O-H, and C-O bonds within the 700-2500 nm range. Instruments use pulsed or steady NIR light sources (LEDs or narrowband lasers) and delicate thermal or photodiode detectors to capture gentle after tissue interaction. NIR light undergoes absorption by water, glucose, lipids, and proteins, and scattering resulting from tissue microstructures. Variations in glucose concentration subtly alter the diffuse scattering coefficient, affecting both the intensity and path size of reflected or transmitted mild.


US 5086229A (1992, Rosenthal et al.): Introduced a handheld NIR unit (600-1100 nm) with supply filter, detector, and processing electronics to quantify glucose through fingers-setting early foundations. US 5823966A (1998, Buchert): BloodVitals insights Advanced continuous NIR monitoring utilizing spectrally selective emission and detection. US 9885698B2 (2018): Emphasized differential reflectance utilizing twin probes to isolate vein from non-vein signals, mitigating pores and skin variability. US 6097975A (2000, BioSensor): Applied narrowband BloodVitals insights mild pulses and comparative filtering to enhance glucose sensitivity via reflection modes. EP 3747363A1: Described multi-wavelength NIR imaging utilizing a finger-cradle and digicam-primarily based machine for snapshot spectrometry. These patents underscore persistent themes: optimization of supply wavelengths, differential measurement to scale back tissue interferences, and mechanical stabilization to ensure repeatable readings-collectively tackling core sign problem points. A June 2024 MDPI study deployed the Glucube® portable NIR system on 60 contributors, capturing 1,500 measurement pairs throughout fasting, pre-/post-prandial, and nocturnal states. ISO15197:2015 compliance: BloodVitals SPO2 Achieved throughout various glucose states.


Algorithm stabilization: Performance improved after every week of adaptation. Weak Signal Intensity: Glucose absorption is faint and overwhelmed by dominant absorbers like water and BloodVitals insights proteins. Spectral Overlap: Requires multivariate statistical methods (PLS, ANN) to extract glucose sign from noise. Physiological Variability: Factors like pores and skin thickness, temperature, and hydration enormously influence readings. Calibration Drift: Models degrade over time